Национальный стандарт ГОСТ Р ИСО 16200-2-2007 "Качество воздуха рабочей зоны. Отбор проб летучих органических соединений с последующей десорбцией растворителем и газохроматографическим анализом. Часть 2. Метод диффузионного отбора проб" (утв. приказом Фед стр. 7

[1] ISO 6141:1984Gas analysis - Calibration gas mixtures - Certificate of mixture preparation
[2] ISO 6145 (all parts)Gas analysis - Preparation of calibration gas mixtures using dynamic volumetric methods
[3] ISO 6349Gas analysis - Preparation of calibration gas mixtures - Permeation method
[4]Posner, J. С and Okenfuss, J. R. Desorption of organic analytes from activated carbon, I: Factors affecting the process, Amer. Ind. Hyg. Assoc. J., 42,1981, pp. 643-646
[5]Posner, J. С Desorption of organic analytesfrom activated carbon, II: Dealing with the problems, Amer. Ind. Hyg. Assoc. J., 42,1981, pp. 647-652
[6]McMurray, J. D., Stollm I., Mitchell, К. М. and Zwicki, R. D. Evaluation of desorption efficiency methods for acetone, Amer. Ind. Hyg. Assoc. J., 50,1989, pp. 520-525
[7]Krajewski J., Gromiec, J. and Dobecki, M. Comparison of methods for determination of desorption efficiencies, Amer. Ind. Hyg. Assoc. J., 41,1980, pp. 531-534
[8]Pannwitz, K.-H. Measurement of concentrations of the vapours of organic solvents in work areas, Part I. Drager review, 56, November 1985, pp. 6-29
[9]Pannwitz, K.-H. Measurement of concentrations of the vapours of organic solvents in work areas, Part II. Drager review, 56, December 1986, pp. 9-14
[10]Pannwitz, K.-H. Measurement of concentrations of the vapours of organic solvents in work areas, Part III. Drager review, 56, September 1988, pp. 22-25
[11]3M Organic Vapour Monitor Sampling and Analysis Guide. September 1996
[12]SKC Air Sampling Guide, 1997. International Edition
[13]Cocheo, V., Boaretto, C and Sacco, P. High uptake rate radial diffusive sampler suitable for both solvent and thermal desorption. Amer. Ind. Hyg. Assoc. J., 57,1996, pp. 897-904
[14]Lugg, G. A. Diffusion coefficients of some organic and other vapours in air. Anal. Chem., 40,1968, pp. 1072-1077
[15]Fuller.E. N., Schettler, P. D. and Giddings, J. С. A new method for prediction of binary gas-phase diffusion coefficients, Ind. Eng. Chem., 58,1966, pp. 19-27
[16]Pannwitz, K.-H. Diffusion coefficients, Drager review, 52, January 1984, pp. 1-8
[17]Feigley, C. E. and Lee, В. М. Determination of sampling rates for organic vapours based on estimated diffusion coefficients, Amer. Ind. Hyg. Assoc. J., 48,1987, pp. 873-876
[18]Feigley, C. E. and Lee, В. М. Determination of sampling rates for organic vapours based on estimated diffusion coefficients, Amer. Ind. Hyg. Assoc. J., 49,1988, pp. 266-269
[19]Hori, H. and Tanaka, I. Effect of face velocity on the performance of diffusive samplers, Ann. Occ. Hyg., 40,1996, pp. 467-476
[20]Health and Safety Executive Protocol for assessing the performance of a diffusive sampler, MDHS 27 HSE, 1994: ISBN 0 7176 0635 X
[21]Cassinelli, M. E., DeLon Hull, R., Crable, J. V. and Teass, A. W. Protocol for the evaluation of passive monitors in diffusive sampling: An alternative approach to workplace monitoring, Ed. Berlin A., Brown R. H. and Saunders K. J., Royal Society of Chemistry, 1986, ISBN 0851863434
[22]Harper, M. and Guild, L. V. Experience in the use of the NIOSH diffusive sampler evaluation protocol, Amer. Ind. Hyg. Assoc. J., 57,1996, pp. 1115-1123
[23] EN 482:1994Workplace atmospheres - General requirements for the performance of procedures for the measurement of chemical agents
[24] ISO 5725 (all parts)Accuracy (trueness and precision) of measurement methods and results
[25]IUPAC, Harmonised protocols for the adoption of standardized analytical methods and for the presentation of their performance characteristics, Pure Appl. Chem., 62,1990, pp. 149-162
[26]Health and Safety Executive Methods for the Determination of Hazardous Substances. Analytical quality in workplace air monitoring. MDHS 71, HSE, 1991: ISBN 0 7176 0366 0
[27]Botnick, E. L., Suga, R. S. and White, К. Т. (eds.) Laboratory Quality Assurance Manual. 2(nd) edition. AIHA Press, Fairfax VA, US, 1997
[28]Health and Safety Executive Methods for the Determination of Hazardous Substances. n-Hexane in air: Laboratory method using charcoal diffusive samplers, solvent desorption and gas chromatography. MDHS 74, HMSO, 1992: ISBN 0 11 885740 1
[29]Mazur,J.F.,Podolak, G.., Esposito, С. G.,Rinehart, D. S. and Gleen.R. E. Evaluation of a passive dosimeter for collection of 2-bromo-2-chloro-1,1,1-trifluoroethane and 2-chloro-1,1,2-trifluoroethyl difluoromethyl ether in hospital operating rooms. Amer. Ind. Hyg. Assoc. J., 41,1980, pp. 317-321
[30]Wright, M. D. Evaluation of the 3M type 3500 monitor for the determination of halothane in air. Health and Safety Executive Internal Report IR/L/OA/85/14
[31]US Occupational Safety and Health Administration, OSHA Manual of Analytical Methods, Vol. 49:
Ethylene Oxide, USDOL/OSHA1989
[32]Rodroguez, S. Y., Gosselink, D. W. and Mullins. H. E. Determination of desorption efficiencies in the 3M 3500 organic vapour monitor. Amer. Ind. Hyg. Assoc. J., 43,1982, pp. 569-574
[33]Mertens, H. and Beste, E. Suitability examination of ORSA-5 diffusive samplers made by Dragewerke AG. Drager review, 58, December 1986, pp. 22-26
[34]Health and Safety Executive Methods for the Determination of Hazardous Substances. Mixed hydrocarbons (C3 to C10) in air. MDHS 60, HMSO, 1992, ISBN 011 88598 6